100%
CO / CQ Đầy đủ
Bảo Hành
12 Tháng Chính Hãng
Giao Hàng
Toàn Quốc 24-48h
Máy phân tích đèn led bo mạch FEASA LED ANALYSERS
Đơn giá tham khảo (chưa VAT):
Liên hệ báo giá dự án Chiết khấu đặc biệt theo số lượng đơn hàng B2B
Hỗ Trợ Kỹ Thuật & Mua Hàng B2B Dự Án:
Cần tư vấn chọn model, thông số kỹ thuật, hồ sơ thầu, hoặc yêu cầu kiểm định hiệu chuẩn ISO 17025?
Thông Số Kỹ Thuật & Chi Tiết Sản Phẩm
[video width="1280" height="720" mp4="https://www.semiki.com/assets/uploads/2024/06/Feasa_LED_Analysers.mp4"][/video]
When choosing which Model is most suitable for your application there are a number of issues to consider. In this regard the choice of Interface is very important.
USB offers a very simple interface to the LED Analyser with no requirement for an additional power supply. Very high baud rates, up to 460800 baud, are available. The RS232 Serial Port is easy to use with a max baud rate of 115200. It requires the use of an external power supply. The 20pin ICT Port can be used in either Frequency Out or Synchronous Serial Mode.
Data sheet: Feasa_LED_Analysers1
DISTRIBUTED BY:
Semiki instrumentation Co., Ltd
Email: sales@semiki.com
Office tel: +84 28 2253 3522
~DOING OUR BEST FOR YOU~
Interface
| Feasa I | Feasa F | |
|---|---|---|
| USB | No | Yes |
| RS232 | Yes | Yes |
| 20 Pin Port – Frequency Out | Yes | No |
| 20 Pin Port – Synchronous Out | Yes | No |
| Daisy Chain | No | Yes |
| External Trigger | Yes | Yes |
Frequency Out
The Frequency Out protocol can be used where access to an RS232 Serial Port is not available. Three frequencies are used to represent the Color and Intensity of the LEDs.Synchronous Serial Port
The Synchronous Serial protocol is suitable when tester resources are limited or no other options are available.Daisy Chain
Multiple LED Analysers can be connected together using the Daisy Chain Connectors. Only one RS232 Serial Port or USB Port is required to connect up to 30 LED Analysers.External Trigger Input
The Feasa I provides an External Trigger Input which can be used to synchronise LED measurements with an external event such as an LED switching on.Led Analyser Test Time
The speed of the test is dependent on the intensity of the LEDs being tested, i.e. Bright LEDs have a shorter Test Time, Dimmer LEDs have a longer Test Time. The capture (measurement) of up to 20 LEDs is done in parallel and can be achieved in times as fast as 102ms depending on the Intensity (Brightness). The data is read back from each fiber sequentially and takes approximately 5ms per fiber, for example:Ultra High Brightness LEDs Test Time
– 1 LED Capture Time is 2ms and Read Back is 5ms, Total 7ms. – 20 LEDs Capture Time is 2ms and Read Back is 100ms, Total 102ms.Dim LEDs Test Time
– 1 LED Capture Time is 650ms and Read Back is 5ms, Total 655ms. – 20 LEDs Capture Time is 650ms and Read Back is 100ms, Total 750ms.USB / RS232 Serial Port – Range Capture Times
| Range | Capture Time |
|---|---|
| C (Auto Capture) | 350ms |
| C1 (Low Intensity) | 650ms |
| C2 (Medium Intensity) | 200ms |
| C3 (High Intensity) | 22ms |
| C4 (Super High Intensity) | 4ms |
| C5 (Ultra High Intensity) | 2ms |
Outputs
| USB / RS232 | |
|---|---|
| – Red, Green, Blue (RGB) | |
| – Hue, Saturation, Intensity (HSI) | |
| – Dominant Wavelength | |
| – CCT | |
| – CIE xy | |
| – CIE u’v’ | |
| Frequency Out | |
| – Hue, Saturation, Intensity (HSI) | |
| Synchronous Serial | |
| – Red, Green, Blue (RGB) | |
| – Hue, Saturation, Intensity (HSI) | |
| – CCT | |
| – CIE xy |
Data sheet: Feasa_LED_Analysers1
Maintenance and calibration :
► We also have calibration certificate attached ( optional ) ► Please re-calibrate after use for a certain period through our purchase store. Local Vietnam : SEMIKI CORP
DISTRIBUTED BY:
Semiki instrumentation Co., Ltd
Email: sales@semiki.com
Office tel: +84 28 2253 3522
~DOING OUR BEST FOR YOU~Sản Phẩm Cùng Nhóm
Xem tất cả FEASA →
TESTO
Báo giá B2B
Đơn giá: Liên hệ báo giá
LUTRON
Báo giá B2B
Đơn giá: Liên hệ báo giá
HIOKI
Báo giá B2B
Đơn giá: Liên hệ báo giá