Hotline / Zalo: 0979 761 016
Bảo hành chính hãng • CO/CQ • ISO 17025 | Báo giá B2B nhanh
SEMIKI Logo
SEMIKI.COM
MALCOM RCX-O hệ thống kiểm tra nhiệt độ, nồng độ oxy trong reflow oven (6 kênh/1,000 ~10,000 ppm) MALCOM Hàng có sẵn
100% CO / CQ Đầy đủ
Bảo Hành 12 Tháng Chính Hãng
Giao Hàng Toàn Quốc 24-48h
Mã SKU: RCX-O Thương hiệu: MALCOM

MALCOM RCX-O hệ thống kiểm tra nhiệt độ, nồng độ oxy trong reflow oven (6 kênh/1,000 ~10,000 ppm)

Đơn giá tham khảo (chưa VAT):
139.790.000 ₫ Giá áp dụng cho 01 đơn vị sản phẩm
Hỗ Trợ Kỹ Thuật & Mua Hàng B2B Dự Án:

Cần tư vấn chọn model, thông số kỹ thuật, hồ sơ thầu, hoặc yêu cầu kiểm định hiệu chuẩn ISO 17025?

Thông Số Kỹ Thuật & Chi Tiết Sản Phẩm

MALCOM Japan 

model: RCX-O

Reflow Checker Memory Unit with O2 Concentration Monitor

MALCOM RCX-O Check the oxygen concentration from the entrance to the exit of the reflow oven! Accurately measure the oxygen concentration on the board! Visualize the entire furnace interior. Measure the oxygen concentration in real time at the board placement position. Compare with the oxygen concentration meter attached to the reflow equipment, allowing for more accurate status confirmation.  ● Profiles changes in oxygen concentration from the entrance to the exit of the reflow oven.  ● Supports measurements during production (heating), enabling efficient work.  ● Select from two measurement ranges depending on the control width (50 to 5,000 ppm, 1,000 to 10,000 ppm).
The MALCOM RCX-O is an optional add-on module, so it does not come as a standalone product with its own set of standard accessories. Instead, it relies on the accessories provided with the main RCM-S or RCX-1 base unit it connects to. 
The overall accessories required to use the system with the O₂ monitor include:
Core System Components & Accessories:
These items are typically included with the main 
RCM-S or  RCX-1
Unit and are essential for the RCX-O to function:
  • Main Memory Unit: An RCM-S unit serves as the "brain" and power supply for the RCX-O module.
  • Heat-resistant case: A standard heat-resistant case (approx. 65 x 245 x 25 mm according to semiki.com) is included with the main system to protect the memory unit during profiling. Note that using the RCX-O module might require a specific, potentially larger, heat-resistant case for the assembled unit.
  • Batteries: Power is supplied from the RCM-S unit, which uses either AAA batteries (x3) or a Ni-MH rechargeable battery pack.
  • USB Cable: For wired data transfer to a PC.
  • Thermocouple Wires: These K-type thermocouple wires are standard for the base unit's temperature measurement function, which typically runs concurrently with O₂ measurement.
  • System Program Software: Dedicated PC software (e.g., TMR-1) is necessary for data analysis and displaying temperature and O₂ concentration profiles simultaneously.

Specification:

Model: RCX-O (Oxygen concentration measurement unit) Maximum measurement time: Approximately 40 minutes Measurement principle: Zirconia limiting current type Measurement range oxygen: 50 to 5,000 ppm 1,000 to 10,000 ppm (choose one) Measurement accuracy: [50 to 5,000 ppm specifications] 50 to 1,000 ppm: 5% ±FS 1,000 to 5,000 ppm: 10% ±FS [1,000 to 10,000 ppm specifications] 1,000 to 10,000 ppm: ±5% FS Power supply (supplied from RCM-S): Nickel-metal hydride batteries (AAA batteries x 3) Long heat-resistant case for RCX: 65 x 370 x 25 mm weight: Approximately 950 g (excluding tray) Maintenance and calibration :  ► We also have calibration certificate attached ( optional ) ► Please re-calibrate after use for a certain period through our purchase store. Local Vietnam : SEMIKI Ins DISTRIBUTED BY: Semiki instrumentation Co., Ltd Email:  sales@semiki.com Office tel: +84 28 2253 3522 ~DOING OUR BEST FOR YOU~  